<?xml version="1.0" encoding="UTF-8"?>
<urlset xmlns="http://www.sitemaps.org/schemas/sitemap/0.9" xmlns:image="http://www.google.com/schemas/sitemap-image/1.1" xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:video="http://www.google.com/schemas/sitemap-video/1.1">
  <url>
    <loc>https://durndell.co.uk/cavities</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.744335-FAVIAEJTQMIBFNZDHXST/imgg-gg3p-BC-DQ--G-4cc1b1b9.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932030.925362-APRTEUCFNHSPOZLCXGLA/imgg-gg3p-BC-DQ-M-1f0d43cb.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932031.11286-ZBCPULHSCKQTWCTIVHHM/imgg-gg3p-BC-DQ-U-4232d553.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.455714-WMYYCPJDXHYXNTHYHZUL/imgg-gg3p-BC-DRQ-b1ca29f7.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Cavities</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/e422fe9f-5eb6-409b-9546-69b85b877934/STRUCTURE+-+cavity+endoscope.png</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/walls</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1c17f6e4-0698-4bd9-bdf1-f24ca5764c30/Damp+Survey.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/7bff628f-6def-4af1-a350-d41fb1f6be75/WALLS+-+the+causes.png</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f88ff5a9-aede-470d-953a-0e56df028618/in-situ-rh-probe-reading-concrete-slab.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/ac3d1c4d-897b-44bc-8b21-b57c50c77c57/20251121T111110.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f3f21e0d-6bee-4bc8-a094-3f4cccd47370/RB0011.jpg</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1e5df1b7-8b34-4c80-9cee-559206f995b6/IMG_7188.JPG</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/floors</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/2c9ee51a-a3a5-4003-9ebc-f3987bf06562/FLOORS+-+the+tests.png</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f88ff5a9-aede-470d-953a-0e56df028618/in-situ-rh-probe-reading-concrete-slab.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/ed2db358-9816-46d8-be0a-fe954365389e/thermal-image-hot-water-leak-under-floor.jpg</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1a02b6e7-8621-4015-8f85-8312bc6c25c9/kitchen-door-threshold-missing-dpm.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1e5df1b7-8b34-4c80-9cee-559206f995b6/IMG_7188.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/6eed4c67-a253-4e1b-ba5a-25aa95a82d9f/FLOORS+-+one+leak+or+two+sources_1.png</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/207c981a-54f1-4f8a-925c-e73e68e07376/FLOORS+-+drying+monitoring+%28optional%29.png</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/thermal</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1c17f6e4-0698-4bd9-bdf1-f24ca5764c30/Damp+Survey.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/b4587961-e559-4816-96d6-a46529c2d718/RELATIVE_HUMIDITY_DAMP_READING.png</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/ac3d1c4d-897b-44bc-8b21-b57c50c77c57/20251121T111110.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/78df0646-1c1a-4881-a8f1-6cc5d9db61f0/Missing_Cavity_Closer.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1e5df1b7-8b34-4c80-9cee-559206f995b6/IMG_7188.JPG</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/monitoring</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.744335-FAVIAEJTQMIBFNZDHXST/imgg-gg3p-BC-DQ--G-4cc1b1b9.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932030.925362-APRTEUCFNHSPOZLCXGLA/imgg-gg3p-BC-DQ-M-1f0d43cb.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932031.11286-ZBCPULHSCKQTWCTIVHHM/imgg-gg3p-BC-DQ-U-4232d553.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.455714-WMYYCPJDXHYXNTHYHZUL/imgg-gg3p-BC-DRQ-b1ca29f7.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Monitoring</image:title>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/disputes</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1c17f6e4-0698-4bd9-bdf1-f24ca5764c30/Damp+Survey.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/7bff628f-6def-4af1-a350-d41fb1f6be75/WALLS+-+the+causes.png</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f88ff5a9-aede-470d-953a-0e56df028618/in-situ-rh-probe-reading-concrete-slab.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/ac3d1c4d-897b-44bc-8b21-b57c50c77c57/20251121T111110.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f3f21e0d-6bee-4bc8-a094-3f4cccd47370/RB0011.jpg</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1e5df1b7-8b34-4c80-9cee-559206f995b6/IMG_7188.JPG</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/home</loc>
    <changefreq>daily</changefreq>
    <priority>1.0</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.744335-FAVIAEJTQMIBFNZDHXST/imgg-gg3p-BC-DQ--G-4cc1b1b9.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932030.925362-APRTEUCFNHSPOZLCXGLA/imgg-gg3p-BC-DQ-M-1f0d43cb.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932031.11286-ZBCPULHSCKQTWCTIVHHM/imgg-gg3p-BC-DQ-U-4232d553.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932029.455714-WMYYCPJDXHYXNTHYHZUL/imgg-gg3p-BC-DRQ-b1ca29f7.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1780932028.996614-UTQBLDRGZFNAGLOVELRR/imgg-gg3p-BC-DQ-Y-0570a11c.png</image:loc>
      <image:title>Home</image:title>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1c17f6e4-0698-4bd9-bdf1-f24ca5764c30/Damp+Survey.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f88ff5a9-aede-470d-953a-0e56df028618/in-situ-rh-probe-reading-concrete-slab.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/ac3d1c4d-897b-44bc-8b21-b57c50c77c57/20251121T111110.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f3f21e0d-6bee-4bc8-a094-3f4cccd47370/RB0011.jpg</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1e5df1b7-8b34-4c80-9cee-559206f995b6/IMG_7188.JPG</image:loc>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f6588ea9-d607-42f5-bdbf-18ee31b69e07/jonathan-durndell-mrics-chartered-surveyor.jpeg</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/about-contact</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/5101d2d4-a3af-4f46-8760-cf42eab4fb58/Jonathan+Durndell+MRICS%2C+Chartered+Building+Surveyor</image:loc>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/fees</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases</loc>
    <changefreq>daily</changefreq>
    <priority>0.75</priority>
    <lastmod>2026-11-21</lastmod>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/awaabs-law-mk-mid-terrace</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-15</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/9ecbbd1b-5885-43ac-b0ec-5a5699105a12/bedroom-ceiling-mould-window-milton-keynes.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Mould growth at upper corner of window reveal – condensation issue documented in Awaab’s Law compliance survey, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1762590636245-XTG7CGTJKBTT8SZHHAVB/Door-Reveal-Mould-milton-keynes.png</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Surface mould to lower door reveal at external wall junction – common cold-bridge location identified during Awaab’s Law damp survey, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/7520b1e9-9fb3-48ea-b463-1f1f0e718843/bedroom-window-reveal-condensation-mould-MK.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Condensation mould forming on bedroom window reveal and cill – evidence from damp and mould inspection in Milton Keynes mid-terrace property</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/6868489d-d3d5-4229-843d-3291a668fd45/bathroom-mould-inspection-awaabs-law-durndell-building-surveyors.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Bathroom ceiling mould above shower light – evidence of poor extract performance identified by Durndell Building Surveyors under Awaab’s Law, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/19f107a1-8795-4bb3-83e4-d6640bf59116/evidence-that-stands-up-damp-survey-protimeter-durndell-building-surveyors.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Protimeter Mini moisture measurement confirming low substrate moisture – Durndell Building Surveyors evidence-based damp investigation, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/bda6dd82-afdb-417a-a4c0-06c6e59aef5e/protimeter-low-wme-reading-dry-substrate.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Moisture meter reading showing dry wall substrate confirming absence of rising or penetrating damp – Milton Keynes compliance damp survey</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/eb7daf59-bec4-4a29-a602-8f3400137ded/bathroom-mastic-mould-milton-keynes.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Black mould growth along bath mastic seal showing inadequate ventilation – Awaab’s Law compliance survey, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/881e779c-f1c0-44a4-b26f-3bd6929538c4/under-sink-leak-kitchen-damp-source.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Under-sink leak in kitchen unit contributing to internal humidity and surface dampness – secondary moisture source identified during Awaab’s Law compliance survey, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/14c8f35a-f4c9-4f5b-a0b0-b6a54565b862/roof-void-extractor-duct-flexi-poor-milton-keynes.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Crushed flexible extract ductwork in loft space reducing fan performance – ventilation compliance issue identified by Durndell Building Surveyors, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/0c810197-f66f-42c9-b54d-007bc5a7104e/bathroom-ventilation-extractor-dusty-milton-keynes.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Bathroom extract grille blocked by dust, restricting airflow – root cause of condensation identified in compliance survey, Milton Keynes</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/75df47c2-b6b2-438f-896a-4f595f99b789/bathroom-mould-walls-poor-extractor-milton-keynes.JPG</image:loc>
      <image:title>Cases - Damp &amp; Mould Survey, Milton Keynes mid-terrace</image:title>
      <image:caption>Condensation and mould staining on upper bathroom wall from poor extract ventilation – damp and mould compliance inspection, Milton Keynes</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/forensic-damp-investigation-school-milton-keynes</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/b0107f37-ec6a-4a5c-9808-4fb436788c64/correct-detail-dpc-dpm-overlap-rising-damp-solution-milton-keynes.PNG</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Correct DPC and DPM overlap detail showing proper waterproofing design to prevent rising damp in school extension – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/b9e384eb-6a8d-4b1a-b1cc-26c4b58dc0f1/existing-detail-damp-proof-membrane-failure-milton-keynes.PNG</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Existing construction detail showing damp-proof membrane and damp-proof course at same level allowing moisture tracking between layers – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/38d9f84c-1f98-4126-8793-80289b4ee773/forensic-damp-investigation-wall-base-moisture-school-extension-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Wall base plaster deterioration and floor inspection revealing moisture at the wall junction during forensic damp investigation in school extension – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/cbfbef18-a1f0-4cbe-b3fe-8c6f822d2fa1/trial-hole-screed-damp-proof-membrane-interface-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Trial hole beneath floor showing underfloor heating conduits and concrete substrate where moisture tracking between DPC and DPM was confirmed – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/c0213569-a9f6-43ae-9cc4-2db7b8694f80/floor-screed-dpm-dpc-interface-damp-proofing-failure-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Close-up of wall base showing damp-proof membrane and damp-proof course at same level, confirming moisture tracking pathway in school extension – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/9325afa5-ba0f-4728-af91-7cda22614657/forensic-damp-investigation-moisture-reading-wall-base-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Moisture reading taken at wall base confirming high damp levels where DPM and DPC were installed at same level during school extension investigation – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/09531784-dcc2-40d1-8623-fc574a4329fc/tide-marks-rising-damp-school-corridor-investigation-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Tide marks and plaster deterioration along school corridor wall showing evidence of rising damp prior to forensic investigation – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/d00dcbce-ebec-44e6-9a3f-643349fc7207/forensic-damp-investigation-salts-influenced-reading-wall-base-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Moisture meter reading taken behind service boxing showing damp surface and salt deposits likely influencing conductivity – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/8312a6df-ce0f-48b4-b1d7-014bda4b1df4/wall-base-investigation-plaster-below-screed-damp-wicking-milton-keynes.jpg</image:loc>
      <image:title>Cases - Forensic Damp Investigation | School Extension Milton Keynes</image:title>
      <image:caption>Wall base investigation showing plaster carried below screed level, allowing moisture from floor slab to wick up into wall structure – Durndell Building Surveyors, Milton Keynes.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/condensation-leaking-drain</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/3d832dc9-e7fe-4dfa-ab82-af2db123f687/water-on-concrete-floor-leaking-drain.JPG</image:loc>
      <image:title>Cases - Mould blamed on condensation: the water under the floor</image:title>
      <image:caption>Water sitting on the floor after days without rain. The source wasn’t the weather.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/605c0c37-5490-4fc7-9f67-e5997f973738/IMG_0242.JPG</image:loc>
      <image:title>Cases - Mould blamed on condensation: the water under the floor</image:title>
      <image:caption>The cast iron drain running beneath the cottage. CCTV later found it blocked and partly collapsed.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1795249526473-576L3SK4JPU34HDT6IFU/moisture-map-damp-floor-victorian-cottage.jpg</image:loc>
      <image:title>Cases - Mould blamed on condensation: the water under the floor</image:title>
      <image:caption>Moisture map of the ground floor. The wettest readings run across the dining room floor.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/kitchen-floor-leak-copper-pipe</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1795250685368-VJRD7OFFO9M52LELU7K0/screed-moisture-map-kitchen-leak.png</image:loc>
      <image:title>Cases - Damp blamed on the new driveway: the leak under the kitchen floor</image:title>
      <image:caption>Floor moisture map showing damp spreading from under the kitchen sink</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/17cf23d5-23f5-40fe-b3a9-38f3e65c6ca2/endoscope-corroded-copper-pipe-wet-screed.jpg</image:loc>
      <image:title>Cases - Damp blamed on the new driveway: the leak under the kitchen floor</image:title>
      <image:caption>Endoscope view of corroded copper pipe and waterlogged screed</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/bbcad0e6-21b1-4eae-be40-9d5583640e80/thermal-image-hot-water-leak-under-floor.jpg</image:loc>
      <image:title>Cases - Damp blamed on the new driveway: the leak under the kitchen floor</image:title>
      <image:caption>Thermal image showing a hot spot from a leaking pipe under the kitchen floor</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/elms-centre-damp-roof-survey</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2025-11-08</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/dc42ab73-baa3-45f9-a0d3-1d86f1f3478f/bay-window-water-ingress-survey.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Damp ceiling finishes above bay window.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/abaf89b5-9765-41e1-b005-c4c7b3a8c4ce/damp-water-ingress-ceiling.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Brown staining to ceilings from leaking roof.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/c4f01e95-44f2-4fad-b181-b2f84490d548/bay-window-damp-survey.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Internal damp ceilings caused by roof failure.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/6c9d13fb-c00f-41a3-8b7c-55ee7c3ee0ee/specialist-damp-survey-roof.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Elm Centre roof survey to establish roof failures and water ingress.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/78702bb9-0024-4f74-b1a5-fde95c825bbc/roof-survey-nhs-property-leaks.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Slate roof, chimney, parapet, bay roofs - roof condition survey.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/c5bfcfb5-3e8f-414a-ba5e-f18d81b16e40/bay-window-roof-survey-defects.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Bay window roof upstand failures - water ingress.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/4215b257-73d7-4695-a78c-58ded662c184/water-ingress-damp-survey-roof-missing-slates.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Missing and slips natural slate roof - roof survey.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/da592c5c-0a35-449d-bd91-637f41388908/damp-ingress-missing-slates-roof.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Ridge tile mortar joints missing &amp; slipped slates.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/6c947904-bd2b-4975-a918-1ce9b52b7b90/banbury-damp-survey-external-rainwater-goods.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Defective rainwater goods causing penetrating damp to walls below.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/2da97d80-4722-40af-9694-8cde2d44e373/roof-void-survey-damp-hip-timber.JPG</image:loc>
      <image:title>Cases - The Elms Centre, Banbury, Oxfordshire</image:title>
      <image:caption>Roof void survey highlighting damp to hip beam.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/damp-mould-investigation</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/7e94612b-2733-4bd6-a485-c4eef0b5c655/ceiling-mould-light-fitting.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Black mould growth on ceiling panel around light fitting due to poor ventilation and leaks.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/02693146-eb47-40d0-abd0-74a3baa0c007/ceiling-mould-damp-damage.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Severe mould growth and water damage visible on ceiling and beam caused by prolonged damp ingress.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/6c9c04db-39c0-45bd-af45-72b111480dd9/ceiling-damp-mould-breakdown.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Collapsed ceiling and visible mould from prolonged dampness in kitchen area.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/13c53ffd-059a-4e55-a7dc-6670a3b109dd/plant-room-water-ingress.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Water damage and debris in plant room caused by leaks affecting electrical equipment.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/a70a7013-00c0-443c-b27a-fcaae825787a/severe-ceiling-water-damage.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Severe water damage to ceiling with exposed wiring following roof leak and damp issues.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/965c1d31-3f04-4a77-99c4-cb55da097f3b/internal-wall-damp-penetration.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Moisture staining on brick wall showing clear signs of penetrating damp.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/d6d9725b-d16d-4200-ae78-1db71a1de147/window-reveal-mould-damp.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Mould and staining around window reveal indicating long-term damp penetration.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/b450ba7d-933b-49f9-972a-8975fcb1f883/roof--valley-gutter-blockage-vegetation.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Blocked roof valley filled with moss and vegetation, restricting drainage.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/9dcf32fa-250f-4567-90bd-611966db657d/pitched-roof-missing-broken-tiles.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Pitched roof with missing and broken tiles creating risk of water penetration.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/dcb2fef6-aa87-487f-a464-8632e876371e/roof-slab-crack-vegetation.JPG</image:loc>
      <image:title>Cases - Buckinghamshire Health Centre</image:title>
      <image:caption>Crack in flat roof asphalt covering with vegetation growth indicating water ingress path.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/hot-water-system-investigation</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/f7261693-c2d2-46b1-b24b-ca49cdf4e8a1/damp-survey-high-value.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Non-invasive damp survey of high-value property to inspect water damage.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/16576522-4180-4e5d-9ae3-6db912fe608f/riser-cupboard-pipework-dap-survey.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Pipework riser cupboard removed to allow inspection of failed pipework.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/fe08e7ab-e2b8-4dc9-bd04-3321dec9da20/water-storage-tank-damp-survey.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Main pipework and water storage tanks for inspection of leaks and damp.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/dd0faa3c-a597-4eca-bae8-b7b02e6f762e/ceiling-pipework-damp-inspection.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Removal of high-quality coffered ceilings for inspection of damp.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/15be7e73-5615-414c-8497-950ac9d2799b/pipework-wall-damp-intrusive.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Removal of wall finishes for the survey of damp and pipework.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/5f22ad5a-f414-4398-b23e-c8135029aa12/damp-ceilings-pipework-location.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Part ceiling removal to inspect failed pipework.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1d243ed9-cda3-46fc-a20d-863156a5f984/ceiling-location-leaking-pikework.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Ceiling removal to replace leaking pipework causing damp.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/2717ea4b-1c2a-404a-bbf3-71d0a8fb971a/stripout-damp-ceilings.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Ceiling survey of failed pipework and damp.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/2806b4c2-ed86-46f6-b93b-f9c13f51c099/damp-location-pipework.JPG</image:loc>
      <image:title>Cases - Hot water system failure: evidence for a solicitor's claim</image:title>
      <image:caption>Roof void survey of water damage caused by pipework faults.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/leak-claim-carbide-testing-concrete-slab</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/e4cd2f96-e60a-426f-8e6e-78760a55b1a1/carbide-moisture-test-concrete-slab.JPG</image:loc>
      <image:title>Cases - Leak claim declined: carbide testing a wet concrete slab</image:title>
      <image:caption>Concrete sample broken out by hand and tested by the carbide method. This measures the moisture in the slab itself, not just the surface.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1a02b6e7-8621-4015-8f85-8312bc6c25c9/kitchen-door-threshold-missing-dpm.JPG</image:loc>
      <image:title>Cases - Leak claim declined: carbide testing a wet concrete slab</image:title>
      <image:caption>At the kitchen door the membrane stops short of the threshold. It's a separate, local defect, not the cause of the wet slab.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/e5fd2f4e-0c38-4168-a6d8-94b5435a9aa2/concrete-floor-moisture-map-leak.png</image:loc>
      <image:title>Cases - Leak claim declined: carbide testing a wet concrete slab</image:title>
      <image:caption>Surface readings mapped across the floor. Moisture peaks at the leak and falls away from it, the pattern of a leak, not of ground moisture.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/4cf76381-61f7-475b-8f65-70bca1df8922/carbide-sample-hole-concrete-slab-kitchen.JPG</image:loc>
      <image:title>Cases - Leak claim declined: carbide testing a wet concrete slab</image:title>
      <image:caption>Sample taken by hand from the exposed kitchen slab near the leak, then double-bagged, sealed and labelled for carbide testing.</image:caption>
    </image:image>
  </url>
  <url>
    <loc>https://durndell.co.uk/cases/wet-floor-after-leak-in-situ-probes</loc>
    <changefreq>monthly</changefreq>
    <priority>0.5</priority>
    <lastmod>2026-11-21</lastmod>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/3ee3ed67-8d91-4234-a7cd-252b29178422/in-situ-rh-probe-concrete-slab.JPG</image:loc>
      <image:title>Cases - Leak blamed for a wet floor: the cause was underneath</image:title>
      <image:caption>One of four humidity probes sealed into the slab. Read in summer and again ten weeks later, every probe stayed above 85% RH, the limit for laying a floor covering." Alt text: "In-situ relative humidity probe set into a concrete floor slab with a moisture meter</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/043eb3aa-493c-4272-a702-cc36782c8cf9/suspended-timber-floor-air-vent-stone-cottage.JPG</image:loc>
      <image:title>Cases - Leak blamed for a wet floor: the cause was underneath</image:title>
      <image:caption>Low-level air vent in the outside wall. It once ventilated a suspended timber floor. Behind it now is solid concrete, so the floor that let the building dry has gone.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/dbb4a4c0-7ed1-4b39-a95d-57e827d733a2/mouldy-plywood-damp-concrete-floor.JPG</image:loc>
      <image:title>Cases - Leak blamed for a wet floor: the cause was underneath</image:title>
      <image:caption>Floor finishes lifted to reveal mould and the bitumen layer on the slab. The bitumen slows drying but doesn't stop moisture coming through, which is why the boards laid on top kept lifting.</image:caption>
    </image:image>
    <image:image>
      <image:loc>https://images.squarespace-cdn.com/content/v1/639c23a4e9e1b669ae401117/1f2cf1b7-a57c-4c7e-b5d7-b8d78b18a963/stone-wall-concrete-slab-ground-moisture-section.png</image:loc>
      <image:title>Cases - Leak blamed for a wet floor: the cause was underneath</image:title>
      <image:caption>Section through the study floor. With no damp-proof membrane, ground moisture rises into the slab. The bitumen and floor finishes above stop it drying, so the moisture moves into the wall, the only place it can evaporate. High ground outside adds moisture to the base of the wall. A buried leak can't yet be ruled out.</image:caption>
    </image:image>
  </url>
</urlset>

